| PRODUCT PREVIEW |
|
TECHNICAL INFORMATION |
|
|
|
|
|
|
 |
|
| FEATURES: |
| Acrylic Rotameters are precision machined from clear acrylic block and fitted with |
| needle valves stream lined in appearance. They are designed to give maximum |
| Accuracy visibility & Ruggedness. |
| FLOATS: |
| Stainless steel, Teflon, PVC or as per requirement. In bigger models guide rods |
| are provided for better stability. |
| METERING VALVE: |
| For Accurate flow control precision machined needle type valves are |
| ACCURACY: |
| Standard Accuracy of 1.5 to 1% at full Scale. Better accuracy on specific |
| requirement. |
| FITTINGS: |
| Top / Bottom or Rear as per requirement in S.S. screwed, Nozzle, with Suitable "0" |
| Rings to avoid leakage. |
| CALIBRATION: |
| Carried out at works individualy using air and water at standard condition. Reliable |
| impirical conversion, are used to calibrate for other fluids. |
| INSTALLATION: |
| Rotameter are ideal for direct Panel mounting because of their neat modular |
| apperance, online is also possible. |
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
|
| TECHNICAL DATA |
|
TECHNICAL SPECIFICATION |
|
|
|
|
|
|
| METERING BODY |
: |
ACRYLIC PLASTIC |
| WETTED PART |
: |
SS / BRASSI PVC / TEFLON |
| FLOAT |
: |
SS / TEFLON / PVC / P.P.1/4" NPT / BSP / SCREWED REAR WITH VALVE. |
| PIPE CONNECTIONS |
: |
AND FANGED TOP BOTTOM / REAR |
| "0" RING |
: |
STD : NEOPRENE / TEFLON VITON SILICON |
| SCALE |
: |
ENGRAVED ON THE BODY |
| PRESS RATION |
: |
TO 100 PSIG STD |
| RATING |
: |
0 PT HIGHER RATING ON SPECIAL APPLICATION |
| TEMP. |
: |
UPTO 70° C |
| ACCURACY |
: |
+ .5 TO + 1% AT F.S. |
|
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
|
|
| PRODUCT PREVIEW |
|
TECHNICAL INFORMATION |
|
|
|
|
|
|
 |
|
| GLASS TUBE ROTAMETER : |
| Glass Tube Rotameter are Precision flow measuring instruments designed on |
| the "Variable Area" Rotameter basis using "TAPERED" Tubes. These instruments |
| Instruments are suitable for service with all available fluid including Acids, Alkalies |
| Corrossive gas and organic Solvents for Temperature upto 150°C with suitable |
| selection of material. |
| METERING TUBES : |
| Extra Thick chemically Resistant annealed and stress Relieved TAPERED glass. |
| FLOATS : |
| Suitable for all corrosive or non corrosive liquids / gases, S.S. Teflon, PVC, |
| etc. |
| FITTINGS : |
| End fittings are either screwed or flanged or for hose connection. |
| CALIBRATION: |
| Calibration is carried out INDIVIDUALY at works using Air and Water at |
| standard condition, with Reliable empirical conversion for other Fluids / Gases. |
| " SPARES ARE READILY AVAILABLE |
| INCLUDING GLASS TUBES" |
| |
|
|
|
|
|
|
| |
|
|
| |
|
|
|
|
|
|
| TECHNICAL DATA |
|
TECHNICAL SPECIFICATION |
|
|
|
|
|
|
| METERING TUBE |
: |
BOROSILICATED TAPERED GLASS |
| FLOAT |
: |
STD : S.S 304, S.S.316 / TEFLON / PVC ETC |
| PACKING / GASKET |
: |
STD : NEOPRENE / TEFLON / SILICON / VITON |
| END FITTING |
|
STD : ALM. BODY WITH MS. COVER WITH TRANSPARENT ACRYLIC CLEAR / |
| |
: |
TOUGHNED GLASS. |
| SHIELDING |
: |
GLASS |
| SCALE |
: |
WHITE ACRYLIC / ALUMINIUM COATED |
| COLOUR |
: |
BLUE / HAMERTONE GREY |
| PRESS: RATING |
: |
UPTO 150 PSIG |
| TEMP. |
: |
UPTO 150 0C |
| ACCURACY |
: |
+ .5 TO + 1% AT F.S. |
|
|
|
|
|
| |
|
|
| |
|
|
| DIGITAL FLOW INDICATOR WITH TOTALIZER |
|
|
|
|
| |
|
|
| |
|
|
|
|
|
|
| PRODUCT PREVIEW |
|
TECHNICAL INFORMATION |
|
|
|
|
|
|
 |
|
| DIGITAL FLOW INDICATOR WITH TOTALLIZER : |
| These are the flow Indicator can be installed on the line Electronic Indication |
| of the Flow in Displayed on a Digital Indicator Device. This Indicating Display |
| can be installed at any continued Position and can be centrally monotored |
| magnetic Indication is also possible with Magnate type Flow Indicator. |
| |
|
|
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|
|
|
|
| PRODUCT PREVIEW |
|
TECHNICAL INFORMATION |
|
|
|
|
|
|
 |
|
| BY PASS ROTAMETER |
| By pass type rotameter are used for linear measurement of fluid flow in |
| conjunction with orifice plates. This is an in expensive method of measuring |
| large flows beyond 20M³ / HR and Line Size 2" and above. Model Rotameter |
| is used to measure flow regardless of main line pipe size. The unit consists of a |
| complete assembly that is to be inserted in the main line and rotameter with |
| calibrated orifice plate which can be assembled to your by pass system. |
| |
|
|
|
|
|
|
| TECHNICAL DATA |
|
TECHNICAL SPECIFICATION |
|
|
|
|
|
|
| TYPE |
: |
BY PASS ROTAMETER |
| MAIN LINE |
: |
M.S FLANGED / S.S / PVC (PP) |
| ROTAMETER |
: |
ACRYLIC / GLASS TUBE / METALIC |
| |
|
ENGRAVED ON BODY / WHITE ACRYLIC / |
| SCALE |
: |
ALU. COATED |
| COLOUR |
: |
BLUE / HAMERTONE GREY |
| END FITTING |
: |
STD . M.S / S.S / PVC (PP) |
| BY PASS LINE |
: |
STD G1 "1/2" S.S / PVC (PP) |
| ISOLATING VALVES |
: |
1/2" G.I. / 1/2 " S.S.316 |
| ORIFICE PLATE |
: |
S.S.304 / PVC / S.S.316 |
| ACCURACY |
: |
+ 2.5% AT F.S |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|