FLOW & LEVEL INSTRUMENTS

ACRYLIC BODY ROTAMETER
 
PRODUCT PREVIEW   TECHNICAL INFORMATION
ACRYLIC BODY ROTAMETER





 
FEATURES:
Acrylic Rotameters are precision machined from clear acrylic block and fitted with
needle valves stream lined in appearance. They are designed to give maximum
Accuracy visibility & Ruggedness.
FLOATS:
Stainless steel, Teflon, PVC or as per requirement. In bigger models guide rods
are provided for better stability.
METERING VALVE:
For Accurate flow control precision machined needle type valves are
ACCURACY:
Standard Accuracy of 1.5 to 1% at full Scale. Better accuracy on specific
requirement.
FITTINGS:
Top / Bottom or Rear as per requirement in S.S. screwed, Nozzle, with Suitable "0"
Rings to avoid leakage.
CALIBRATION:
Carried out at works individualy using air and water at standard condition. Reliable
impirical conversion, are used to calibrate for other fluids.
INSTALLATION:
Rotameter are ideal for direct Panel mounting because of their neat modular
apperance, online is also possible.
 
 
TECHNICAL DATA   TECHNICAL SPECIFICATION
METERING BODY : ACRYLIC PLASTIC
WETTED PART : SS / BRASSI PVC / TEFLON
FLOAT : SS / TEFLON / PVC / P.P.1/4" NPT / BSP / SCREWED REAR WITH VALVE.
PIPE CONNECTIONS : AND FANGED TOP BOTTOM / REAR
"0" RING : STD : NEOPRENE / TEFLON VITON SILICON
SCALE : ENGRAVED ON THE BODY
PRESS RATION : TO 100 PSIG STD
RATING : 0 PT HIGHER RATING ON SPECIAL APPLICATION
TEMP. : UPTO 70° C
ACCURACY : + .5 TO + 1% AT F.S.
 
'JI' Glass Tube Rotameter
PRODUCT PREVIEW   TECHNICAL INFORMATION


 
 

Glass Tube Rotameter are Precision flow measuing instruments designed on the "Variable Area" Rotameter basis using "TAPERED' Tubes. These instruments are suitable for service with all aviable fliuid including Acids. Alkalies Corrosive gas and origanic Solvents for Temperature upto 150° C with suitable selection of material.

 
Metering Tubes :
Extra Thick chemically Resistant annealed and stress Relivered Tapered glass.

Floates:

Suitable for all corrosive or non corrosive liquids/gases, S.S. Teflon, PVC, etc.

Fittings :

End fittings are either screwed or flanges or for hose connection.

Calibration:
Calibration is carries out Individually at works using Air and Water at standard condition, with Reliable empirical conversion for other Fluids/Gases.
"SPARES ARE READILY AVAILABLE INCLUDING GLASS TUBES"
 
 
 
Technical Data
METERING TUBE Borosilicated Tapered Glass
FLOAT STD : S.S. 304, S.S. 316/TEFLON/PVS ETC
PACKING/GASKET STD : NEOPRENE / TEFLON / SILICON / VITON
END FITTING STD : ALM. Body with Ms. Cover with Transparent Acrylic ClearS
SHIELDING Toughned Glass
SCALE Glass
COLOUR White Acrylic / Aluminium Coated
PRESS:RATING Blue / Hamertone Gray
TEMP.

Upto 150 °C

ACCURACY + .5 To + 1 % At F.S.
   
 
 
METAL TUBE ROTAMETER
PRODUCT PREVIEW   TECHNICAL INFORMATION
metal-tube  
Principle of measurement:

The variable area flowmeter measures the flow rate of liquids and gases in pipe lines. It contains a vertical metal tube.

with an orifice (or a conical tube which widens towards the top) through which the measured medium flows.

The float (which can move in the tube in the vertical plane) settles at a specific level, if the forces acting on it are in equilibrium, such that the weight of the float is identical to the sum of the buoyancy force and the flow force. The level of the float in the conical measuring tube is proportional to the flow rate. A magnet located in the float and a magnet follow-up system enable the float’s level in the tube to be indicated via a pointer.

A cam mechanism linearizes the flow rate. The flow rate is then read from the scale according to the pointer position.

General Specification:

Size: ½” to 6” and DN 15 to DN 150

End Connection: Flanged to ANSI, DIN standard
Pressure rating: DN 15 to DN 50 (1/2” to 2”) - 4.0 MPa (580 psi)
DN 80 to DN150 (3” to 6”) - 1.6 MPa (232 psi)
Flow range: 2.5 - 100000 LPH (water) or 0.07 - 3000 m3/hr (air)

Process temperature rating: Normal- H1: -40 to 100 deg C
High temperature version- H2: -80 to 250 deg C

Ambient temperature limit: -25 deg C to + 55 deg C
Materials: Standard: SS 316,
Optional: SS 316 Ti or PTFE lined SS316
Range ability: For sizes up to 4” (DN100) - 10:1 For 6”: 5:1
Accuracy: Standard: +/- 2.5% Full Scale; Special: +/- 1.5% Full Scales

     
Digital Flow Indicator with Totalizer
 
PRODUCT PREVIEW   TECHNICAL INFORMATION


 
 

Principle of measurement:

The variable area flowmeter measures the flow rate of liquids and gases in pipe lines. It contains a vertical metal tube.

with an orifice (or a conical tube which widens towards the top) through which the measured medium flows.

The float (which can move in the tube in the vertical plane) settles at a specific level, if the forces acting on it are in equilibrium, such that the weight of the float is identical to the sum of the buoyancy force and the flow force. The level of the float in the conical measuring tube is proportional to the flow rate. A magnet located in the float and a magnet follow-up system enable the float’s level in the tube to be indicated via a pointer. A cam mechanism

linearizes the flow rate. The flow rate is then read from the scale according to the pointer position.

 

General Specification:

Size: ½” to 6” and DN 15 to DN 150

End Connection: Flanged to ANSI, DIN standard
Pressure rating: DN 15 to DN 50 (1/2” to 2”) - 4.0 MPa (580 psi)
DN 80 to DN150 (3” to 6”) - 1.6 MPa (232 psi)
Flow range: 2.5 - 100000 LPH (water) or 0.07 - 3000 m3/hr (air)

Process temperature rating: Normal- H1: -40 to 100 deg C
High temperature version- H2: -80 to 250 deg C

Ambient temperature limit: -25 deg C to + 55 deg C
Materials: Standard: SS 316,
Optional: SS 316 Ti or PTFE lined SS316
Range ability: For sizes up to 4” (DN100) - 10:1 For 6”: 5:1
Accuracy: Standard: +/- 2.5% Full Scale; Special: +/- 1.5% Full Scales

 
 
 

PURGE ROTAMETER WITH DP REGULATOR

PURGE ROTAMETER WITH DP REGULATOR
 

Item

Purge Rotameter with D.P. regulator

Maximum Pressure rating

12 Kg./cm2

Service

Air

Flow Range

Please confirm

Body material

Die cast aluminium with stove colour finish

Metering tube

Borosilicate glass

Float

SS304

Packing

Teflon

Diaphragm

Nylon Impregnated Neoprene

Needle valve

Integral

End connection

¼” NPT(F)

Connection location

Side & top

Body of D.P. regulator

Die cast aluminium

Make

Ji

 
 
 
 
   
Temperature Instruments Dial Thermometers - Chemical / Laboratory Glass Thermometers - Industrial Marine / Glass Thermometers- Electronic Temperature Indicators & Controller - Portable Temperature Indicator / Thermohygrometers - Digital Thermometer cum Hygrometer - RTD'S & Thermocouples - Thermocouple Probes For Portable Temperature Indicator - Extruders - Compensating Cables - Temperature Recorders - Temperature Switches - Temperature Indicator Crayons
Pressure Instruments Pressure Gauges - Manometers - Dead Weight Testers / Comparison Testers - Pressure Switches - Pressure Recorders - Digital Pressure Indicators / Controllers
Flow & Level Instruments Rotameter / Flow Meter - Level Gauges - Level Switches
Temp & Pressure Instruments Accessories Thermowell -  Pulsation Snubber - Needle Valve (Isolation Valve) - Manifolds Valve - Quick Fitting Adapters & Reducers - Ferrule Fittings - Syphon - Gauge Cock - Pulsation Dampener - Over Pressure protector (gauge saver)
Test & Calibration Calibration Certificate Traceable to National Standard - Temperature Calibration bath- Hand Held Pressure Cum Vacuum Pump - Hand Held Hydraulic Pressure Pump - Hand Held Low Pressure & Vacuum Pump - Hand held vaccum / pressure pump without digital pressure gauge - Digital Pressure Gauge - Digital Pressure Gauge Low Range - Dead Weight Vacuum Tester - Comparison Pressure Test Pump, Comparison Vacuum Test Pump - Dead Weight Pressure Tester
   
 
Home - About Us - Products - Clients - Certificates - Enquiry - Contact